{"id":2181,"date":"2022-08-26T09:43:16","date_gmt":"2022-08-26T04:13:16","guid":{"rendered":"https:\/\/www.kewaunee.in\/blog\/?p=2181"},"modified":"2024-07-17T17:15:13","modified_gmt":"2024-07-17T11:45:13","slug":"laboratory-hvac-supply-exhaust-duct-design","status":"publish","type":"post","link":"https:\/\/www.kewaunee.in\/blog\/laboratory-hvac-supply-exhaust-duct-design\/","title":{"rendered":"Laboratory HVAC: Supply &#038; Exhaust Duct Design"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row full_width=&#8221;stretch_row&#8221; equal_height=&#8221;yes&#8221; content_placement=&#8221;middle&#8221; css=&#8221;.vc_custom_1594037823219{margin-top: 0px !important;margin-bottom: 0px !important;padding-top: 40px !important;padding-bottom: 40px !important;}&#8221;][vc_column]<h1 class=\"boc_heading  al_left  \"  style=\"margin-bottom: 20px;margin-top: 0px;color: #333;\"><span>Laboratory HVAC: Supply &amp; Exhaust Duct Design<\/span><\/h1>[vc_column_text]<span style=\"font-weight: 400;\">An important aspect of laboratory HVAC system is the ducts. There are two key elements to factor in for laboratory duct design &#8211; the primary supply ducts and the exhaust ducts \u2013 to ensure the performance and safety of the laboratory environment.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Typically, for the supply duct, the general practices for all buildings can be used in the selection of duct materials for laboratories. This is because most supply ductwork may not encounter sufficient concentrations of hazardous laboratory materials.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">However, the exhaust duct systems design requires more considerations due to the hazardous materials contained in the exhaust airstreams.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">In this blog, we compare the key design elements recommended by ASHRAE for the laboratory duct design.<\/span>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<table class=\"fortuna_table\">\n<thead>\n<tr>\n<th><strong>ELEMENT<\/strong><\/th>\n<th><strong>DESCRIPTION<\/strong><\/th>\n<th><strong>SUPPLY DUCT<\/strong><\/th>\n<th><strong>EXHAUST DUCT<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><span style=\"font-weight: 400;\">Ambient Temperature<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Higher ambient temperatures relative to the supply air temperature can create condensation on the outside of the ductwork. Condensation on ductwork can eventually cause corrosion of the ductwork.<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Y<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Y<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Duct velocities and pressures<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Low-pressure ductwork is often made of thinner material than higher pressure ductwork, but it requires a larger duct to move the same volume of air as a high-pressure system.<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Y<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Y<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Length and arrangement of the ductwork<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Lengthy runs of ductwork result in larger supply air heat gains or losses and require additional cooling and heating capacity or additional insulation.<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Y<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Y<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Nature of hood effluents<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Knowledge of the current and future effluents and their possible concentrations is necessary to assess the materials required to handle the exhaust.<\/span><\/td>\n<td><\/td>\n<td><span style=\"font-weight: 400;\">Y<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Effluent Temperature<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Effluent temperature is also a concern for condensation. High-temperature effluents can cool off significantly in a lengthy section of duct.<\/span><\/td>\n<td><\/td>\n<td><span style=\"font-weight: 400;\">Y<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Variance in exhaust air volume<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Knowledge of variance in exhaust air volume helps in maintaining needed duct velocities.<\/span><\/td>\n<td><\/td>\n<td><span style=\"font-weight: 400;\">Y<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Flame spread and smoke developed ratings for duct materials<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Knowledge of the rating for the materials considered for ductwork is required to meet national, local, and state regulations.<\/span><\/td>\n<td><\/td>\n<td><span style=\"font-weight: 400;\">Y<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><span style=\"font-weight: 400;\">Kewaunee <\/span><a href=\"https:\/\/www.kewaunee.in\/advisory.php\"><span style=\"font-weight: 400;\">advisory services<\/span><\/a><span style=\"font-weight: 400;\"> are a unique blend of strategy and execution. We tap into our 113+ years of experience, hands-on learning from various industry segments, and multi-geography field work to deliver tangible business outcomes to our customers.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Our experts with knowledge of turnkey laboratory services and compliances guide you from start to finish. Leveraging the latest Industry 4.0 technologies, we help you in getting all your lab requirements right. <\/span><a href=\"https:\/\/www.kewaunee.in\/contact-us.php\"><span style=\"font-weight: 400;\">Talk to us<\/span><\/a><span style=\"font-weight: 400;\"> before you start your next lab project.<\/span>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row full_width=&#8221;stretch_row&#8221; equal_height=&#8221;yes&#8221; content_placement=&#8221;middle&#8221; css=&#8221;.vc_custom_1594037823219{margin-top: 0px !important;margin-bottom: 0px !important;padding-top: 40px !important;padding-bottom: 40px !important;}&#8221;][vc_column][vc_column_text]An important aspect of laboratory HVAC system is the ducts. There are two key elements to factor in for laboratory duct design &#8211; the primary supply ducts and the exhaust ducts \u2013 to ensure the performance and safety of the laboratory environment. Typically, for the supply duct, the<\/p>\n<div class=\"h10\"><\/div>\n<p><a class=\"more-link1\" href=\"https:\/\/www.kewaunee.in\/blog\/laboratory-hvac-supply-exhaust-duct-design\/\">Read more<\/a><\/p>\n","protected":false},"author":2,"featured_media":2182,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[103,108,61,22,64],"tags":[57,393,392,177,79,169,167,181,391],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v21.8 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Laboratory HVAC: Supply &amp; Exhaust Duct Design - Kewaunee<\/title>\n<meta name=\"description\" content=\"Compare the key design elements recommended by ASHRAE for the laboratory duct design. Discover expert tips for efficient laboratory HVAC supply and exhaust duct design.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.kewaunee.in\/blog\/laboratory-hvac-supply-exhaust-duct-design\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Laboratory HVAC: Supply &amp; Exhaust Duct Design - Kewaunee\" \/>\n<meta property=\"og:description\" content=\"Compare the key design elements recommended by ASHRAE for the laboratory duct design. Discover expert tips for efficient laboratory HVAC supply and exhaust duct design.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.kewaunee.in\/blog\/laboratory-hvac-supply-exhaust-duct-design\/\" \/>\n<meta property=\"article:published_time\" content=\"2022-08-26T04:13:16+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-07-17T11:45:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.kewaunee.in\/blog\/wp-content\/uploads\/2022\/08\/Laboratory-HVAC-Supply-Exhaust-Duct-Design-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1266\" \/>\n\t<meta property=\"og:image:height\" content=\"2560\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Kewaunee International Group\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Kewaunee International Group\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.kewaunee.in\/blog\/laboratory-hvac-supply-exhaust-duct-design\/\",\"url\":\"https:\/\/www.kewaunee.in\/blog\/laboratory-hvac-supply-exhaust-duct-design\/\",\"name\":\"Laboratory HVAC: Supply & Exhaust Duct Design - Kewaunee\",\"isPartOf\":{\"@id\":\"https:\/\/www.kewaunee.in\/blog\/#website\"},\"datePublished\":\"2022-08-26T04:13:16+00:00\",\"dateModified\":\"2024-07-17T11:45:13+00:00\",\"author\":{\"@id\":\"https:\/\/www.kewaunee.in\/blog\/#\/schema\/person\/8984b794f6a03b8701a044f24c072f1a\"},\"description\":\"Compare the key design elements recommended by ASHRAE for the laboratory duct design. Discover expert tips for efficient laboratory HVAC supply and exhaust duct design.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.kewaunee.in\/blog\/laboratory-hvac-supply-exhaust-duct-design\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.kewaunee.in\/blog\/laboratory-hvac-supply-exhaust-duct-design\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.kewaunee.in\/blog\/laboratory-hvac-supply-exhaust-duct-design\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.kewaunee.in\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Laboratory HVAC: Supply &#038; Exhaust Duct Design\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.kewaunee.in\/blog\/#website\",\"url\":\"https:\/\/www.kewaunee.in\/blog\/\",\"name\":\"\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.kewaunee.in\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.kewaunee.in\/blog\/#\/schema\/person\/8984b794f6a03b8701a044f24c072f1a\",\"name\":\"Kewaunee International Group\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.kewaunee.in\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/ef98529dacaa04a728210d20f23a4522?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/ef98529dacaa04a728210d20f23a4522?s=96&d=mm&r=g\",\"caption\":\"Kewaunee International Group\"},\"description\":\"Kewaunee, the global leader in total laboratory solutions, empowers organisations to achieve competitive advantage through safe, efficient, and contemporary laboratories. In existence since 1906, Kewaunee powers the laboratories for over 5,000 customers in more than 100 countries.\",\"url\":\"https:\/\/www.kewaunee.in\/blog\/author\/users\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Laboratory HVAC: Supply & Exhaust Duct Design - Kewaunee","description":"Compare the key design elements recommended by ASHRAE for the laboratory duct design. Discover expert tips for efficient laboratory HVAC supply and exhaust duct design.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.kewaunee.in\/blog\/laboratory-hvac-supply-exhaust-duct-design\/","og_locale":"en_US","og_type":"article","og_title":"Laboratory HVAC: Supply & Exhaust Duct Design - Kewaunee","og_description":"Compare the key design elements recommended by ASHRAE for the laboratory duct design. Discover expert tips for efficient laboratory HVAC supply and exhaust duct design.","og_url":"https:\/\/www.kewaunee.in\/blog\/laboratory-hvac-supply-exhaust-duct-design\/","article_published_time":"2022-08-26T04:13:16+00:00","article_modified_time":"2024-07-17T11:45:13+00:00","og_image":[{"width":1266,"height":2560,"url":"https:\/\/www.kewaunee.in\/blog\/wp-content\/uploads\/2022\/08\/Laboratory-HVAC-Supply-Exhaust-Duct-Design-scaled.jpg","type":"image\/jpeg"}],"author":"Kewaunee International Group","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Kewaunee International Group","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.kewaunee.in\/blog\/laboratory-hvac-supply-exhaust-duct-design\/","url":"https:\/\/www.kewaunee.in\/blog\/laboratory-hvac-supply-exhaust-duct-design\/","name":"Laboratory HVAC: Supply & Exhaust Duct Design - Kewaunee","isPartOf":{"@id":"https:\/\/www.kewaunee.in\/blog\/#website"},"datePublished":"2022-08-26T04:13:16+00:00","dateModified":"2024-07-17T11:45:13+00:00","author":{"@id":"https:\/\/www.kewaunee.in\/blog\/#\/schema\/person\/8984b794f6a03b8701a044f24c072f1a"},"description":"Compare the key design elements recommended by ASHRAE for the laboratory duct design. Discover expert tips for efficient laboratory HVAC supply and exhaust duct design.","breadcrumb":{"@id":"https:\/\/www.kewaunee.in\/blog\/laboratory-hvac-supply-exhaust-duct-design\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.kewaunee.in\/blog\/laboratory-hvac-supply-exhaust-duct-design\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.kewaunee.in\/blog\/laboratory-hvac-supply-exhaust-duct-design\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.kewaunee.in\/blog\/"},{"@type":"ListItem","position":2,"name":"Laboratory HVAC: Supply &#038; Exhaust Duct Design"}]},{"@type":"WebSite","@id":"https:\/\/www.kewaunee.in\/blog\/#website","url":"https:\/\/www.kewaunee.in\/blog\/","name":"","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.kewaunee.in\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.kewaunee.in\/blog\/#\/schema\/person\/8984b794f6a03b8701a044f24c072f1a","name":"Kewaunee International Group","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.kewaunee.in\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/ef98529dacaa04a728210d20f23a4522?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ef98529dacaa04a728210d20f23a4522?s=96&d=mm&r=g","caption":"Kewaunee International Group"},"description":"Kewaunee, the global leader in total laboratory solutions, empowers organisations to achieve competitive advantage through safe, efficient, and contemporary laboratories. In existence since 1906, Kewaunee powers the laboratories for over 5,000 customers in more than 100 countries.","url":"https:\/\/www.kewaunee.in\/blog\/author\/users\/"}]}},"_links":{"self":[{"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/posts\/2181"}],"collection":[{"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/comments?post=2181"}],"version-history":[{"count":2,"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/posts\/2181\/revisions"}],"predecessor-version":[{"id":2573,"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/posts\/2181\/revisions\/2573"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/media\/2182"}],"wp:attachment":[{"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/media?parent=2181"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/categories?post=2181"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/tags?post=2181"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}