{"id":1868,"date":"2021-10-29T14:01:15","date_gmt":"2021-10-29T08:31:15","guid":{"rendered":"https:\/\/www.kewaunee.in\/blog\/?p=1868"},"modified":"2024-07-17T17:34:06","modified_gmt":"2024-07-17T12:04:06","slug":"local-exhaust-ventilation-how-to-choose-them","status":"publish","type":"post","link":"https:\/\/www.kewaunee.in\/blog\/local-exhaust-ventilation-how-to-choose-them\/","title":{"rendered":"Local Exhaust Ventilation &#8211; How to choose them?"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row full_width=&#8221;stretch_row&#8221; equal_height=&#8221;yes&#8221; content_placement=&#8221;middle&#8221; css=&#8221;.vc_custom_1594037823219{margin-top: 0px !important;margin-bottom: 0px !important;padding-top: 40px !important;padding-bottom: 40px !important;}&#8221;][vc_column]<h1 class=\"boc_heading  al_left  \"  style=\"margin-bottom: 20px;margin-top: 0px;color: #333;\"><span>Local Exhaust Ventilation &#8211; How to choose them?<\/span><\/h1>[vc_column_text]<span style=\"font-weight: 400;\">A local exhaust ventilation (LEV) systems is required to ensure that lab personnel are protected from dangerous fumes &amp; contaminants. That being said, it\u2019s a very user-specific equipment and must be made in accordance to their requirements. So, how does one go about that process? You can the criteria in the infographic down below and make better choices the next time you\u2019re ordering an LEV.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">If you\u2019re looking to order an LEV, we at Kewaunee International can help you with the entire design, installation, and maintenance process. A list of our certified LEV systems can be found <\/span><a href=\"https:\/\/www.kewaunee.in\/local-exhaust-ventilation.php\"><span style=\"font-weight: 400;\">here<\/span><\/a><span style=\"font-weight: 400;\">. <\/span>[\/vc_column_text][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<table class=\"fortuna_table\">\n<tbody>\n<tr>\n<td><strong>Criteria<\/strong><\/td>\n<td><strong>Key pointers<\/strong><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Purpose of the LEV<\/span><\/td>\n<td>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">What experiments will be conducted?<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">What is the process demands?<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">What contaminants will be present?<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">What is the utility of it for the employer &amp; employees?<\/span><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Design of the LEV<\/span><\/td>\n<td>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">System must not be designed in isolation but account for other equipment too<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">For e.g. Are there any windows or ventilation systems nearby? What is the air movement in the room?<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Ensure integration of the LEV with other components of the laboratory<\/span><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Source &amp; Type of contaminant<\/span><\/td>\n<td>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Where is the contaminant coming from? What is the nature of the contaminant?<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">For e.g. Is it buoyant like hot fume? Directional (grinding\/cutting)?<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Also need to consider whether it\u2019s dispersed in air or propelled into the air<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Ducting is installed accordingly \u2013 to ensure direct route for contaminant to reach the discharge point<\/span><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Air cleaning &amp; filtering systems<\/span><\/td>\n<td>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Install cleaning systems that are in line with the air movement<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Accounts for discharge plume &amp; topography of the area<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Must be made in line with the commissioning party\u2019s specifications<\/span><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Performance indicator instruments<\/span><\/td>\n<td>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Mandatory to install performance indications to monitor performance at any point in time<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">E.g. manometer on hood ducts<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Staff must be trained to use, install, and maintain the equipment<\/span><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-weight: 400;\">Source: LEV Guidance, Health &amp; Safety Control<\/span>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][\/vc_column][\/vc_row][vc_row][vc_column][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row full_width=&#8221;stretch_row&#8221; equal_height=&#8221;yes&#8221; content_placement=&#8221;middle&#8221; css=&#8221;.vc_custom_1594037823219{margin-top: 0px !important;margin-bottom: 0px !important;padding-top: 40px !important;padding-bottom: 40px !important;}&#8221;][vc_column][vc_column_text]A local exhaust ventilation (LEV) systems is required to ensure that lab personnel are protected from dangerous fumes &amp; contaminants. That being said, it\u2019s a very user-specific equipment and must be made in accordance to their requirements. So, how does one go about that process? You can the<\/p>\n<div class=\"h10\"><\/div>\n<p><a class=\"more-link1\" href=\"https:\/\/www.kewaunee.in\/blog\/local-exhaust-ventilation-how-to-choose-them\/\">Read more<\/a><\/p>\n","protected":false},"author":2,"featured_media":1869,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[64,212],"tags":[213,200,181,185,214],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v21.8 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Choosing Local Exhaust Ventilation Systems | Kewaunee<\/title>\n<meta name=\"description\" content=\"Protect lab staff with proper local exhaust ventilation (LEV) systems. Learn key tips for choosing the right one to combat fumes and contaminants.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.kewaunee.in\/blog\/local-exhaust-ventilation-how-to-choose-them\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Choosing Local Exhaust Ventilation Systems | Kewaunee\" \/>\n<meta property=\"og:description\" content=\"Protect lab staff with proper local exhaust ventilation (LEV) systems. Learn key tips for choosing the right one to combat fumes and contaminants.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.kewaunee.in\/blog\/local-exhaust-ventilation-how-to-choose-them\/\" \/>\n<meta property=\"article:published_time\" content=\"2021-10-29T08:31:15+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-07-17T12:04:06+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.kewaunee.in\/blog\/wp-content\/uploads\/2021\/10\/Local-Exhaust-Ventilation-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"2451\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Kewaunee International Group\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Kewaunee International Group\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.kewaunee.in\/blog\/local-exhaust-ventilation-how-to-choose-them\/\",\"url\":\"https:\/\/www.kewaunee.in\/blog\/local-exhaust-ventilation-how-to-choose-them\/\",\"name\":\"Choosing Local Exhaust Ventilation Systems | Kewaunee\",\"isPartOf\":{\"@id\":\"https:\/\/www.kewaunee.in\/blog\/#website\"},\"datePublished\":\"2021-10-29T08:31:15+00:00\",\"dateModified\":\"2024-07-17T12:04:06+00:00\",\"author\":{\"@id\":\"https:\/\/www.kewaunee.in\/blog\/#\/schema\/person\/8984b794f6a03b8701a044f24c072f1a\"},\"description\":\"Protect lab staff with proper local exhaust ventilation (LEV) systems. Learn key tips for choosing the right one to combat fumes and contaminants.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.kewaunee.in\/blog\/local-exhaust-ventilation-how-to-choose-them\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.kewaunee.in\/blog\/local-exhaust-ventilation-how-to-choose-them\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.kewaunee.in\/blog\/local-exhaust-ventilation-how-to-choose-them\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.kewaunee.in\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Local Exhaust Ventilation &#8211; How to choose them?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.kewaunee.in\/blog\/#website\",\"url\":\"https:\/\/www.kewaunee.in\/blog\/\",\"name\":\"\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.kewaunee.in\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.kewaunee.in\/blog\/#\/schema\/person\/8984b794f6a03b8701a044f24c072f1a\",\"name\":\"Kewaunee International Group\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.kewaunee.in\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/ef98529dacaa04a728210d20f23a4522?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/ef98529dacaa04a728210d20f23a4522?s=96&d=mm&r=g\",\"caption\":\"Kewaunee International Group\"},\"description\":\"Kewaunee, the global leader in total laboratory solutions, empowers organisations to achieve competitive advantage through safe, efficient, and contemporary laboratories. In existence since 1906, Kewaunee powers the laboratories for over 5,000 customers in more than 100 countries.\",\"url\":\"https:\/\/www.kewaunee.in\/blog\/author\/users\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Choosing Local Exhaust Ventilation Systems | Kewaunee","description":"Protect lab staff with proper local exhaust ventilation (LEV) systems. Learn key tips for choosing the right one to combat fumes and contaminants.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.kewaunee.in\/blog\/local-exhaust-ventilation-how-to-choose-them\/","og_locale":"en_US","og_type":"article","og_title":"Choosing Local Exhaust Ventilation Systems | Kewaunee","og_description":"Protect lab staff with proper local exhaust ventilation (LEV) systems. Learn key tips for choosing the right one to combat fumes and contaminants.","og_url":"https:\/\/www.kewaunee.in\/blog\/local-exhaust-ventilation-how-to-choose-them\/","article_published_time":"2021-10-29T08:31:15+00:00","article_modified_time":"2024-07-17T12:04:06+00:00","og_image":[{"width":2560,"height":2451,"url":"https:\/\/www.kewaunee.in\/blog\/wp-content\/uploads\/2021\/10\/Local-Exhaust-Ventilation-scaled.jpg","type":"image\/jpeg"}],"author":"Kewaunee International Group","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Kewaunee International Group","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.kewaunee.in\/blog\/local-exhaust-ventilation-how-to-choose-them\/","url":"https:\/\/www.kewaunee.in\/blog\/local-exhaust-ventilation-how-to-choose-them\/","name":"Choosing Local Exhaust Ventilation Systems | Kewaunee","isPartOf":{"@id":"https:\/\/www.kewaunee.in\/blog\/#website"},"datePublished":"2021-10-29T08:31:15+00:00","dateModified":"2024-07-17T12:04:06+00:00","author":{"@id":"https:\/\/www.kewaunee.in\/blog\/#\/schema\/person\/8984b794f6a03b8701a044f24c072f1a"},"description":"Protect lab staff with proper local exhaust ventilation (LEV) systems. Learn key tips for choosing the right one to combat fumes and contaminants.","breadcrumb":{"@id":"https:\/\/www.kewaunee.in\/blog\/local-exhaust-ventilation-how-to-choose-them\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.kewaunee.in\/blog\/local-exhaust-ventilation-how-to-choose-them\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.kewaunee.in\/blog\/local-exhaust-ventilation-how-to-choose-them\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.kewaunee.in\/blog\/"},{"@type":"ListItem","position":2,"name":"Local Exhaust Ventilation &#8211; How to choose them?"}]},{"@type":"WebSite","@id":"https:\/\/www.kewaunee.in\/blog\/#website","url":"https:\/\/www.kewaunee.in\/blog\/","name":"","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.kewaunee.in\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.kewaunee.in\/blog\/#\/schema\/person\/8984b794f6a03b8701a044f24c072f1a","name":"Kewaunee International Group","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.kewaunee.in\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/ef98529dacaa04a728210d20f23a4522?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ef98529dacaa04a728210d20f23a4522?s=96&d=mm&r=g","caption":"Kewaunee International Group"},"description":"Kewaunee, the global leader in total laboratory solutions, empowers organisations to achieve competitive advantage through safe, efficient, and contemporary laboratories. In existence since 1906, Kewaunee powers the laboratories for over 5,000 customers in more than 100 countries.","url":"https:\/\/www.kewaunee.in\/blog\/author\/users\/"}]}},"_links":{"self":[{"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/posts\/1868"}],"collection":[{"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/comments?post=1868"}],"version-history":[{"count":2,"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/posts\/1868\/revisions"}],"predecessor-version":[{"id":2589,"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/posts\/1868\/revisions\/2589"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/media\/1869"}],"wp:attachment":[{"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/media?parent=1868"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/categories?post=1868"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kewaunee.in\/blog\/wp-json\/wp\/v2\/tags?post=1868"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}